Compact air dryer
Desiccant dryers in the DC series can lower the pressure dew point of the compressed air to -70 ℃. They combine reliable system design, high energy efficiency and extremely low maintenance costs.The dryer is timed to switch towers based on a standard NEMA cycle.
This is a heatless dryer of the pressure reduction self-regenerating system which does not use heat for regeneration of the desiccant. Stable supply of ultra dry air provides dependable frost protection for your control valves and lines while producing dry compressed air for sensitive processes at minimal cost.
Specifications
MODEL | Flow rate | End Conn. | Dimensions in mm | Weight | ||
---|---|---|---|---|---|---|
SCFM | In / Out | Height | Width | Depth | Kg | |
GFCD 5 | 5 | 1/2" | 585 | 300 | 120 | 10 |
GFCD 10 | 10 | 1/2" | 750 | 300 | 120 | 13 |
GFCD 20 | 20 | 1/2" | 1025 | 300 | 200 | 18 |
GFCD 30 | 30 | 1/2" | 940 | 533 | 200 | 30 |
GFCD 45 | 45 | 1/2" | 1075 | 533 | 200 | 36 |
GFCD 60 | 60 | 3/4" | 1225 | 533 | 200 | 58 |
GFCD 100 | 100 | 1" | 1225 | 533 | 200 | 71 |
Operating Conditions | ||||||
Normal | Maximum | |||||
Working Pressure | 7 to 12.5 Bar | 16 Bar | ||||
Inlet Temperature | 45°C | 60°C | ||||
Dew Point | -40°C | -60°C | ||||
Above flow rates are at 7 Bar,35 ℃,Standard Power supply 220V, 50Hz. Optional 12V DC, 24V DC available on request. | ||||||
Usage/Application: | ◼ Instrument and Control Air ◼Process Control Instruments ◼ Textile Machines◼Machine tools ◼ Bearing air ◼ Air Motors and Heavy Air motor ◼ miniature◼Packaging machine ◼ Pneumatic cylinder ◼ Sensors in fluid technology ◼ Sand blasting unit ◼ Handling of food and beverages ◼ Semi conductor manufacturing ◼ Wind tunnels◼Pharmaceutical manufacturing ◼ Conveyance of hygroscopic products ◼ Paint spray and Powder coating |
High Pressure Dryer upto 400Bar( Dessicant Type )
The term "desiccant dryer"refers to a broad class of dryers. Other terms commonly used are regenerative dryer and twin tower dryer, and to a lesser extent adsorption dryer.
The compressed air is passed through a pressure vessel with two "towers" filled with a desiccant material. This desiccant material attracts the water from the compressed air via adsorbtion. As the water clings to the desiccant, the desiccant "bed" becomes saturated. The dryer is timed to switch towers based on a standard NEMA cycle, once this cycle completes some compressed air from the system is used to "purge" the saturated desiccant bed by simply blowing the water that has adhered to the desiccant off.
High pressure adsorption compressed air dryer consists from control valves, controller with LED display and two columns filled with desiccant. Springs in the columns make surethat the desiccant beads will not move during operation. Proven robust design enables efficient and reliable operation, fast installation and simple maintenance.
Specifications
MODEL | Flow rate at 7 Bar,35°C | End Conn. | Dimensions in mm | Weight | ||||
---|---|---|---|---|---|---|---|---|
LPM | Nm3/Hr | SCFM | In / Out | Height | Width | Depth | Kg | |
Series GLP | ( Available Pressure rating from 40 Bar to 100 Bar @ regeneration air loss of 4 to 5.5% max ) | |||||||
GLP-68 | 1133 | 68 | 40 | 1/4" | 1325 | 625 | 450 | 50 |
GLP-115 | 1916 | 115 | 68 | 3/8" | 1450 | 625 | 450 | 60 |
GLP-195 | 3250 | 195 | 115 | 3/8" | 1575 | 625 | 450 | 92 |
GLP-382 | 6366 | 382 | 225 | 1/2" | 2125 | 850 | 525 | 116 |
GLP-635 | 10583 | 635 | 375 | 3/4" | 2175 | 850 | 525 | 162 |
Series - GMP | ( Available Pressure rating from 100 Bar to 250 Bar @ regeneration air loss of 4 to 5.5% max ) | |||||||
GMP-100 | 1666 | 100 | 58 | 1/4" | 1350 | 625 | 475 | 65 |
GMP-150 | 2500 | 150 | 88 | 3/8" | 1420 | 625 | 475 | 78 |
GMP-200 | 3333 | 200 | 117 | 3/8" | 1540 | 625 | 475 | 96 |
GMP-250 | 4166 | 250 | 150 | 3/8" | 1410 | 725 | 475 | 104 |
GMP-300 | 5000 | 300 | 176 | 3/8" | 1480 | 725 | 475 | 150 |
GMP-400 | 6666 | 400 | 235 | 1/2" | 1560 | 875 | 550 | 165 |
GMP-500 | 8333 | 500 | 295 | 1/2" | 1620 | 875 | 550 | 185 |
GMP-600 | 10000 | 600 | 350 | 1/2" | 1830 | 875 | 550 | 240 |
GMP-1100 | 18333 | 1100 | 650 | 3/4" | 2110 | 875 | 550 | 290 |
Series-GHP | ( Available Pressure rating from 250 Bar to 400 Bar @ regeneration air loss of 4 to 5.5% max ) | |||||||
GHP-125 | 2083 | 125 | 74 | 1/4" | 1320 | 650 | 475 | 103 |
GHP-225 | 3750 | 225 | 132 | 3/8" | 1380 | 650 | 475 | 130 |
GHP-325 | 5417 | 325 | 190 | 3/8" | 1440 | 650 | 475 | 148 |
GHP-425 | 7083 | 425 | 250 | 1/2" | 1580 | 650 | 475 | 160 |
GHP-525 | 8750 | 525 | 310 | 3/4" | 1620 | 875 | 650 | 240 |
Operating Conditions | ||||||||
Normal | Maximum | |||||||
Inlet Temperature | 25°C to 45°C | 55°C | ||||||
Dew Point | -40°C | -70°C | ||||||
Above flow rates are at 7 Bar,35 ℃,Standard Power supply 220V, 50Hz. Optional 12V DC, 24V DC available on request. | ||||||||
Usage/Application: | ◼ Instrument and Control Air ◼Process Control Instruments ◼ Textile Machines◼Machine tools ◼ Bearing air ◼ Air Motors and Heavy Air motor ◼ miniature◼Packaging machine ◼ Pneumatic cylinder ◼ Sensors in fluid technology ◼ Sand blasting unit ◼ Handling of food and beverages ◼ Semi conductor manufacturing ◼ Wind tunnels◼Pharmaceutical manufacturing ◼ Conveyance of hygroscopic products ◼ Paint spray and Powder coating |
Refrigerated air dryer
Refrigeration dryers employ two heat exchangers, one for air-to-air and one for air-to-refrigeration. However, there is also a single Trisab heat exchanger that combines both functions. The compressors used in this type of dryer are usually of the hermetic type and the most common gas used is R-134a. The goal of having two heat exchangers is that the cold outgoing air cools down the hot incoming air and reduces the size of compressor required. At the same time the increase in the temperature of outgoing air prevents re-condensation.
Commonly a coalesing prefilter is installed immediately upstream of a refrigerated dryer to remove lubricating oil and other contaminants that have the potential to foul the dryer's heat exchangers.
Specifications
MODEL | Flow rate | End Conn. | Dimensions in mm | Weight | |||
---|---|---|---|---|---|---|---|
M3/Hr | SCFM | In / Out | Height | Width | Depth | Kg | |
GRD-20 | 20 | 12 | 1/2" | 460 | 590 | 550 | 38 |
GRD-32 | 32 | 19 | 1/2" | 460 | 590 | 550 | 40 |
GRD-51 | 51 | 30 | 3/4" | 460 | 590 | 550 | 43 |
GRD-54 | 54 | 32 | 3/4" | 460 | 590 | 550 | 38 |
GRD-105 | 105 | 62 | 3/4" | 460 | 590 | 550 | 40 |
GRD-135 | 135 | 79 | 1" | 460 | 590 | 550 | 43 |
GRD-180 | 180 | 106 | 1" | 595 | 690 | 680 | 61 |
GRD-250 | 250 | 147 | 1" | 595 | 860 | 860 | 81 |
GRD-300 | 300 | 177 | 1 1/4" | 595 | 860 | 860 | 96 |
GRD-360 | 360 | 212 | 1 1/2" | 595 | 860 | 860 | 109 |
GRD-450 | 450 | 265 | 2" | 595 | 860 | 860 | 114 |
GRD-588 | 588 | 346 | 2" | 630 | 1200 | 960 | 216 |
GRD-708 | 708 | 417 | 2" | 630 | 1200 | 960 | 225 |
GRD-828 | 828 | 487 | 2 1/2" | 870 | 1710 | 1200 | 248 |
GRD-1008 | 1008 | 593 | 2 1/2" | 870 | 1710 | 1200 | 298 |
GRD-1260 | 1260 | 742 | 2 1/2" | 870 | 1710 | 1200 | 327 |
GRD-1560 | 1560 | 918 | NB 80 | 870 | 1710 | 1200 | 375 |
GRD-1890 | 1890 | 1112 | NB 80 | 870 | 1710 | 1200 | 460 |
GRD-2520 | 2520 | 1483 | NB 100 | 1050 | 1810 | 1450 | 525 |
GRD-3090 | 3090 | 1819 | NB 100 | 1050 | 1810 | 1450 | 585 |
GRD-3630 | 3530 | 2137 | NB 100 | 1450 | 2050 | 1650 | 690 |
Operating Conditions | |||||||
Normal | Maximum | ||||||
Working Pressure | 7 to 12.5 Bar | 16 Bar | |||||
Inlet Temperature | 25°C | 55°C | |||||
Dew Point | -3°C | -10 °C | |||||
Above flow rates are at 7 Bar,35 ℃,Standard Power supply ; Model GRD20 to 708 220V/1Ph,50Hz and GRD828 to 3660 440V/3Ph,50Hz. | |||||||
Usage/Application: | ◼ Instrument and Control Air ◼Process Control Instruments ◼ Textile Machines◼Machine tools ◼ Bearing air ◼ Air Motors and Heavy Air motor ◼ miniature◼Packaging machine ◼ Pneumatic cylinder ◼ Sensors in fluid technology ◼ Sand blasting unit ◼ Handling of food and beverages ◼ Semi conductor manufacturing ◼ Wind tunnels◼Pharmaceutical manufacturing ◼ Conveyance of hygroscopic products ◼ Paint spray and Powder coating |